1. Misregistering
Cause: Uneven gripping force of the paper feeder teeth, worn tooth pads (the plastic tooth pads have a lifespan of approximately six months), radial runout of the cam roller (error exceeding 0.02mm), or misaligned screen.
Handling:
Adjust the compression of the paper feeder spring and replace worn tooth pads.
Replace the cam roller and calibrate the radial runout.
2. Electrical System Failure
Symptom: Motor failure to start, abnormal speed control, poor contactor engagement.
Troubleshooting:
Check the coils of the intermediate relays (such as KA2 and KA3) for burnout and poor contact.
Test the speed potentiometer (WT2) and electromagnetic speed controller (such as EA2) for proper function.
3. Abnormal Paper Feeding
Cause: Clutch (YA02) coil burnout, the sheet gap control tooth not touching ground, or a faulty relay (KA01). Handling: Replace damaged parts, reset the paper feed button (SB03), or adjust the position of the electric tooth.
4. "Close/Close" Failure
Fault: Burned-out coil of the close solenoid (YA4), stuck relay (KA9), or offset sheet detector (SQ9).
Solution: Repair or replace the solenoid and calibrate the detector position.
5. "Mechanical Jam or Unstable Movement"
Possible Cause: Bearing wear (clearance exceeding 0.1mm), insufficient lubrication, or loose drive belt.
Maintenance Recommendation: Clean the paper guide roller regularly, add grease, and check roller parallelism.
6. "Paper Break"
Cause: Tight edge of paper roll, ink deposits on the paper guide roller, excessive tension, or loose paper guide roller core.
Handling: Clean ink deposits on the paper guide roller and adjust the tension to a reasonable range.
Check the levelness of the paper guide roller and replace worn bearings. 7. Water/Ink Supply Problems
Water supply problems: Excessive water causes ink emulsification, while insufficient water causes insufficient plate wetting.
Ink supply problems: Uneven ink roller pressure (increase pressure in winter, reduce pressure in summer) or filming on the ink roller.
Note: Some faults require reference to the device manual. For example, to reset error codes (such as E006-E009), press the "STP" key to cancel.